Posts tagged with "efficiency"



Graphic with carrier-based, carrier-free and new formulated system with CIP
25. July 2018
Dry Powder Inhaler (DPI) could offer a propellant-free, easy-to-use powder form ensuring better stability than liquid dosae forms. Therefore the development of traditional carrier-based and carrier-free new generation systems is a determinative factor in the field of DPI formulation. The purpose of our research work was to combine these two systems, utilizing their beneficial properties to produce a novel pulmonary drug delivery system containing ciprofloxacin hydrochloride (CIP). Co-spray...

29. March 2018
Docetaxel (DTX) is a chemotherapy drug that can be used for different type of cancers. Due to polysorbate 80, the excipient in the formulation, acute hypertensivity reaction is observed after intravenous administration. The development of oral formulation for DTX has always been problematic as the bioavailability of the drug is shown to be low due to P-glycoprotein efflux transporters and the intestinal metabolism by CYP3A4 enzymes. The objective of this study is to develop novel DTX in situ...

04. September 2017
Abstract The aim of this study was to develop and characterize sustained release vildagliptin (VLG) loaded Eudragit® RS-100 microspheres. The microspheres were prepared by single emulsion [oil-in-oil (O/O)] solvent evaporation method. Plackett–Burman design (PBD) was employed by using Design-Expert®Software to screen and understand impact of five independent formulation factors such as Eudragit® RS-100 (A), span-80 (B), acetone (C), methanol (D), stirring speed (E) affecting on...
03. March 2017
Abstract A 23 Factorial design of cissus-gelatin B polymer blends was developed to formulate amodiaquine HCl-artesunate (AQ-AS) microparticles by varying the polymer blend concentration (2 %w/v, 5 %w/v), crosslinking time (0.5 h, 1 h) and glutaraldehye volume (0.5 ml, 1 ml). The formulations were evaluated using drug entrapment efficiency (EE), particle size, polydispersity index, thermal behaviour with differential scanning calorimetry, crystallinity with powder X-ray diffraction, morphology...
23. January 2017
Abstract The main objective of the present paper has been the development and study of two new biodegradable polyurethanes, PU(dithiodiethanol-DTDI) and PU[(iPr)Man-DTDI], to be used as sustained matrix forming excipients. Furthermore, their capacity to act as excipient for colon drug delivery systems has been evaluated. Thus, SeDeM diagrams have been obtained to investigate their suitability to be processed through a direct compression process. Matrices containing 10–30% w/w of the polymers...
06. May 2016
The main goal of any drug delivery system is to achieve desired concentration of the drug in blood or tissue, which is therapeutically effective and nontoxic for a prolonged period. Various attempts have been made to develop gastroretentive delivery systems such as high density system, swelling, floating system. The recent developments of FDDS including the physiological and formulation variables affecting gastric retention, approaches to design single-unit and multiple-unit floating systems,...
08. April 2016
Aim: The main objective of the present research work was to develop floating microspheres of cefditoren pivoxel (CP) to provide the delivery of the drug at a sustained rate. Materials and Methods: Floating microspheres of CP were prepared by solvent evaporation technique using hydroxypropyl methylcellulose (HPMC) K4M and ethyl cellulose as the rate controlling polymers. The optimization of formulation was carried out by 32 factorial design using two factors; a total amount of polymer (X1) and...
05. March 2016
Solubility parameters of HPMCAS have not yet been investigated intensively. On this account total and three dimensional solubility parameters of HPMCAS were determined by using different experimental as well as computational methods. In addition, solubility properties of HPMCAS in a huge number of solvents were tested and a Teas plot for HPMCAS was created. The total solubility parameter of about 24 MPa0.5 was confirmed by various procedures and compared with values of plasticizers. 20 common...

Show more